Service Water Piping Wall Thinning

Service Water Piping Wall Thinning

In-house inspection of a service water pipe elbow revealed thinning of the pipe walls due to erosion and/or corrosion. HEA mapped measurements taken of the wall thinning onto a detailed finite element model of the elbow. Analysis of this model indicated that stresses...

Class 1 Piping Analysis

Class 1 Piping Analysis

A Motor Operated Valve was replaced with a heavier valve, requiring reanalysis of the Pressurizer Valve Piping. HEA performed a Class 1 piping analysis considering dynamic fluid transient loading and thermal stratification effects.

Spend Fuel Pool Impact Analysis

Spend Fuel Pool Impact Analysis

HEA determined the seismic displacement of a suspended crane hook load as part of an ISFSI project. Impact of a hook load into the structure was a primary concern. HEA used a computer model to accurately represent the crane, surrounding superstructure, and ground...

Dry Shielded Canister

Dry Shielded Canister

HEA evaluated the structural integrity of the Dry Shielded Canister (DSC) and internals when subjected to an accident-scenario side-drop. Non-linear effects such as material plasticity, contact, and time-history loading were considered.