Bullet and Blast Resistant Enclosure (BBRE) Support Structure
Challenge: A BBRE booth which is 10' x 12' x 10' tall is to be installed 12 feet above ground level for observation purposes. The structure will be subject to a high blast load of 25 psi incident pressure. Resolution: In order to reduce the load effects on the support...
Motorized LAPD Target Lift System
Challenge: To verify the structural adequacy of a motorized aluminum target lift system to support its self-weight, dynamic, and seismic loads. Special attention was required to account for the dynamic vertical movement of the motorized portion of the target lift...
Blast Related Bathrooms